View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0000802 | Starship Simulator | Magellan Class | public | 2023-05-23 04:59 | 2025-04-06 20:12 |
| Reporter | InGameReport | Assigned To | QATeam | ||
| Priority | high | Severity | major | Reproducibility | have not tried |
| Status | closed | Resolution | no change required | ||
| Product Version | 0.223.6.9 | ||||
| Summary | 0000802: Status of electrical switches not saved | ||||
| Description | I disconnected the reactor on the Main Battery Distributor and then logged out. When I logged back in, the switch has been reconnected. | ||||
| Steps To Reproduce | Disconnect main reactor on Main Battery Distributor on G deck in engineering. Log out. Log back in and check the status of the switch on the Main Battery Distributor. | ||||
| Tags | Electrical System | ||||
| BuildVersion | |||||
| GameMode | Single Player | ||||
| Deck | G | ||||
| GalaxyCoords | -25850, 50, 50 | ||||
| LocalCoords | 4627659489280, 6408313503744, 12822208577536 | ||||
| Camera | Loc=[X=-213.489 Y=-814.927 Z=-1641.642] Rot=[P=-12.327414 Y=-104.375036 R=0.000000] | ||||
| Level | /Game/Starships/Magellan_Class/Levels/Magellan_Class | ||||
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2023-05-23 04:59 | InGameReport | New Issue | |
| 2023-05-23 04:59 | InGameReport | Assigned To | => QATeam |
| 2023-05-23 18:13 | Scotty | Note Added: 0000917 | |
| 2023-05-23 18:13 | Scotty | Tag Attached: Electrical System | |
| 2023-05-23 18:13 | Scotty | Assigned To | QATeam => Developers |
| 2023-05-23 18:13 | Scotty | Status | new => assigned |
| 2023-05-28 13:48 |
|
Relationship added | has duplicate 0000824 |
| 2023-06-08 14:42 | claire | Summary | Status of electrical switches not saved => Reminder - Status of electrical switches not saved |
| 2023-06-09 16:55 | claire | Severity | minor => block |
| 2023-10-19 03:15 | claire | Severity | block => minor |
| 2023-10-19 03:15 | claire | Summary | Reminder - Status of electrical switches not saved => Status of electrical switches not saved |
| 2023-10-19 20:35 | claire | Assigned To | Developers => QATeam |
| 2023-10-19 20:35 | claire | Priority | none => high |
| 2023-10-19 20:35 | claire | Severity | minor => major |
| 2023-10-19 20:35 | claire | Status | assigned => confirmed |
| 2024-05-04 15:21 | Scotty | Assigned To | QATeam => Developers |
| 2025-04-06 20:12 | claire | Assigned To | Developers => QATeam |
| 2025-04-06 20:12 | claire | Status | confirmed => closed |
| 2025-04-06 20:12 | claire | Resolution | open => no change required |
| 2025-04-06 20:12 | claire | Note Added: 0001934 |