View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0000375 | Starship Simulator | Magellan Class | public | 2022-09-06 14:06 | 2022-09-20 23:24 |
| Reporter | InGameReport | Assigned To | QATeam | ||
| Priority | none | Severity | major | Reproducibility | always |
| Status | closed | Resolution | fixed | ||
| Platform | Windows | ||||
| Product Version | 0.220.8 | ||||
| Fixed in Version | 0.220.12 | ||||
| Summary | 0000375: MASTER TICKET: Doors are not syncing in multiplayer. | ||||
| Description | Door panels aren't sync between clients. While the icons update, the actual status of the door does not. Guests are also able to walk through closed/locked doors. The code that's used to lock the door can be seen from the other side of the door while the other player is entering it. | ||||
| Steps To Reproduce | 1. Player Host sets the door to manual mode. 2. Player Host then closes the door. 3. Player B tries to change the mode of the door to auto. 4. Player B attempts to go through the door, but the door will not open. | ||||
| Additional Information | Confirmed. -MS | ||||
| Tags | Console UI | ||||
| BuildVersion | |||||
| GameMode | Multiplayer - Host | ||||
| Deck | All | ||||
| GalaxyCoords | |||||
| LocalCoords | |||||
| Camera | Loc=[X=2914.541 Y=-254.019 Z=210.003] Rot=[P=-15.195038 Y=98.070587 R=0.000000] | ||||
| Level | /Game/Starships/Magellan_Class/Levels/Magellan_Class | ||||
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2022-09-06 14:06 | InGameReport | New Issue | |
| 2022-09-06 14:06 | InGameReport | Assigned To | => QATeam |
| 2022-09-06 15:05 |
|
Description Updated | |
| 2022-09-06 15:05 |
|
Steps to Reproduce Updated | |
| 2022-09-06 15:05 |
|
Additional Information Updated | |
| 2022-09-06 15:05 |
|
Deck | A => All |
| 2022-09-06 15:05 |
|
Assigned To | QATeam => Developers |
| 2022-09-06 15:05 |
|
Severity | minor => major |
| 2022-09-06 15:05 |
|
Status | new => assigned |
| 2022-09-06 23:20 |
|
Relationship added | has duplicate 0000391 |
| 2022-09-07 20:18 |
|
Tag Attached: Console UI | |
| 2022-09-10 15:19 | claire | Relationship added | has duplicate 0000442 |
| 2022-09-11 16:47 |
|
Relationship added | has duplicate 0000460 |
| 2022-09-12 16:28 | DanGovier | Summary | Door Mode Not Properly Sync'd => MASTER TICKET: Doors are not syncing in multiplayer. |
| 2022-09-12 16:28 | DanGovier | Description Updated | |
| 2022-09-12 16:28 | DanGovier | Steps to Reproduce Updated | |
| 2022-09-12 16:28 | DanGovier | Additional Information Updated | |
| 2022-09-12 23:34 | claire | Relationship added | has duplicate 0000290 |
| 2022-09-20 13:59 | DanGovier | Assigned To | Developers => QATeam |
| 2022-09-20 13:59 | DanGovier | Status | assigned => resolved |
| 2022-09-20 13:59 | DanGovier | Resolution | open => fixed |
| 2022-09-20 13:59 | DanGovier | Fixed in Version | => 0.220.12 |
| 2022-09-20 13:59 | DanGovier | Note Added: 0000652 | |
| 2022-09-20 23:24 | claire | Status | resolved => closed |